Abstract

A method is presented to quantify thermal fatigue in the CPV die-attach from meteorological data. A comparative study between cities demonstrates a significant difference in the accumulated damage. These differences are most sensitive to the number of larger (ΔT) thermal cycles experienced for a location. High frequency data (<1/min) may be required to most accurately employ this method.

Keywords

Photovoltaic cells – Thermal fatigue; Solar concentrators – Thermal fatigue; Solar energy; Thermal fatigue