Zero Energy House for the Southern Nevada Area

Document Type

Conference Proceeding

Publication Date

8-6-2005

Publication Title

Solar Engineering 2005

Publisher

American Society of Mechanical Engineers

First page number:

33

Last page number:

40

Abstract

Las Vegas, Nevada, is one of the country’s most rapidly growing cities. To accommodate this growth, a great deal of home building takes place in Clark County, where the city is located. Builders can sell virtually as many houses as they can construct. All of these houses require utility services that, in general, have to be developed. These, of course, include water, electrical power and natural gas. With the high cooling loads required in this environment, the summer demand peaks for electricity are particularly severe. The emphasis of this paper was placed on the energy conservation methods for a planned zero energy residential home for the Southern Nevada area, which would enable net zero electric energy consumption from the local utilities over a year period. Although also important, the cost outcome of the project was considered a secondary issue. The energy analysis was arranged in three principal parts: • Reduction of heating and cooling loads through implementation of sound envelope construction • Use of highly energy efficient A/C, gas furnace, and lights • Solar control and utilization The computer simulation package Energy 10 version 1.6 is employed during the envelope, A/C, furnace and energyefficient light analysis. The software allows modeling and simulating of a buildings performance based on inputs such as geographical location, building type, orientation, construction materials used and others. The model selected for this study is reflective of the local construction practices, is a single-family one story, 1,610 ft2 residential house with north facing façade and an attached two-car garage, which in this paper is called the “Base Case”. As a result of the energy analysis performed in this paper, the low-energy house (Modified Case) was created. The Modified Case has the identical orientation and floor plan. Implementation of the full spectrum of energy conserving features yielded a dramatic 105% saving on the annual electrical energy consumption by the Modified Case house when compared to the house built according to the local practices. In addition, the space heating and space cooling energy consumptions were reduced by 96% and 72% respectively. Details of the simulations and the final design details are given in the paper.

Keywords

Dwellings – Energy consumption; Ecological houses; Electric power consumption; Energy conservation; Nevada – Las Vegas

Disciplines

Electro-Mechanical Systems | Environmental Design | Mechanical Engineering | Oil, Gas, and Energy | Sustainability

Language

English

Comments

Conference held: August 6-12, 2005, Orlando, Florida

Permissions

Use Find in Your Library, contact the author, or interlibrary loan to garner a copy of the item. Publisher policy does not allow archiving the final published version. If a post-print (author's peer-reviewed manuscript) is allowed and available, or publisher policy changes, the item will be deposited.

UNLV article access

Search your library

Share

COinS