Fatigue Testing and Retrofit Details of High- Mast Lighting Towers

Document Type

Article

Publication Date

1-1-2016

Publication Title

Engineering Journal (American Institute of Steel Construction)

Volume

53

Issue

1

First page number:

61

Last page number:

72

Abstract

Fatigue cracking has been the cause of a number of high-mast lighting tower (HMLT) failures throughout the United States. In almost every case, forensic evaluations have shown cracking initiates and propagates due to wind-induced fatigue at mainly the base plate-to-tube wall connection detail or the hand-hole weld detail. Subsequent inspections of HMLT inventories have revealed a number of additional cases of fatigue cracking in various stages. Simply replacing the towers is not an economically feasible alternative because thousands of HMLTs are in use along major highways across the United States. As a result, strategies to retrofit existing HMLTs are needed. Results from laboratory testing performed on two HMLT retrofit configurations are presented. Both retrofits provided an increase in fatigue life compared with the as-built HMLTs. The retrofit strategies are employed without removing the pole from the foundation using simple bolting techniques and moderately skilled labor, providing cost savings for owners and increasing safety for the motoring public.


Search your library

Share

COinS